Human machine interface manufacturer today: Inherent human weaknesses: people have inherent weaknesses such as forgetfulness, error-prone, inattentiveness and emotional instability. A well-designed human-machine interface should minimize the amount of user memory when operating and using, and should strive to avoid possible errors; The user’s knowledge and education: the user’s education level determines his knowledge and experience of the computer system. China is the world’s largest market in terms of HMI demand, but it is not the world’s highest market in terms of HMI product sales, which means that low-end HMI users occupy a large share in China. The rapid development of national brands in recent years, taking low prices and other strategies, is attacking the low-end market in a big way, and has occupied a dominant position in the low-end market in China, winning the recognition of the majority of users. International brands are also gradually developing their economic products to capture the share of the low-end market. As a result, the overall performance of domestic HMI manufacturers has shown rapid growth due to their steady presence in the low-end market. Find even more information at https://www.mochuan-drives.com/products-56168.
Reasonable Structural Type: There are two structural types: main module and extended module. The average price of each I/O point of the integral PLC is cheaper than that of the module type, and the volume is relatively small, which is generally used in the small control system with a fixed system process; The function expansion of module plc is flexible and convenient, and there is a large choice in the number of I/O points, the ratio of input points to output points, the type of I/O modules…etc, and the maintenance is convenient, generally in more complex control systems.
Interaction design is subordinate to the product system and is a strong support and refinement to successful product design. If we use the system theory point of view, interaction design is a subsystem of the product design system. Design Principles: The following principles should be considered for the design of human machine interface. The basic user-centered design principle: In the design process of the system, designers should grasp the characteristics of users and discover the needs of users. Users’ opinions should be constantly sought and consulted throughout the development process of the system. The design decisions of the system should be integrated with the users’ work and application environment, and the users’ requirements for the system must be understood. The best way is to involve real users in the development, so that developers can properly understand the needs and goals of users, and the system will be more successful.
Choosing the right industrial hmi touch screen panel and plc can not only adapt to the electrical room’s multi-interference operation environment, but also enable each cabinet to achieve intelligent operation management, intelligent maintenance safety, intelligent new energy generation, etc., in order to achieve the goal of enhancing the electrical room’s core competitive advantage and promoting the sustainable development of electricity. Find additional information at https://www.mochuan-drives.com/.
Human-Computer Interaction (HCI): The science of designing, evaluating, and implementing interactive computing systems for use by people and the study of these phenomena. HCI and human-computer interface are two concepts that are closely related but not identical. The RelationShip Between Human Computer Interaction and HMI: Human-computer interaction is the interaction between a human and a machine, which is essentially the interaction between a human and a computer. Or from a broader perspective: HCI refers to the interaction between a human and a machine containing a computer.
It is good to choose a brand according to the needing of the customers or the market. But it is not for selecting a brand to decide, or more about to focus on its performance parameters, and to be used the functions achieved. Actually there is an attractive story behind the famous brand. So to choose a brand, try to achieve high practicality, to avoide waste one’s talent on a petty job. For example, Siemens, Mitsubishi, Proface, Panasonic brand…etc with a good performance, but before decision to select them, should consider, how many performance of HMI panel will be used for the project? Whether the cost paid matches the performance used on the project?
How To Solve Communication Failure Between HMI Operator Interface And PLC? When communication fails, some customers guess that it may be a problem with the touch screen all-in-one machine or the interface. Online simulation is to bypass the touch screen, use the PLC to connect directly to the computer, use our configuration software, connect the PLC’s own communication cable to the computer, conduct online simulation and see if the project can communicate.
The Macro instructions of HMI Human Machine Interface are based on C language and the system is developed on Linux. There are multi-types of HMI panel, mainly three types, multi touch capacitive hmi panel, plastic shell enconomic resistive hmi touchscreen panel and metal shell wide-temperature resistive touch screen and small home screen to meet different requirement from application scenarios and market needing. There are rich serial port such as rs485, rs232, rs422, ethernet etc to meet the master and slave to use. Mochuan human machine interface manufacturer suppors the size from 4.3inch to 32inch.
The size range is 4.3inch, 7inch, 9.7inch, 10.1inch, 12inch and 15inch, with ethernet, RS485, RS232 and RS422 to meet different application using. If you have the requirement of HMI, it is good to description of your application and what function wanna realize, then the correct and the most suitable model will be recommended to you. Mochuan Drives offers three series of plc programmable logic controller, there are switch control and motion control with very strong power for choosing. Offering free software, demo, 36months warranty, mature solution. And one-to-one technical supporting online to fast solve the customer technical question. Supporting to take the video to solve the technical question, that is service do you need?
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.